Setup points for overvoltage setting

Setup points for overvoltage setting
To correctly set the overvoltage trigger, follow the steps outlined below:

1. Connect the Digital Meter:
2. Use a digital meter to probe the GND and OVV points on the circuit.
3. Set Regulator Voltage:
4. Ensure the voltage regulator is set to 14.7 volts.
5. Adjust the OVV Adjustor:
6. While the regulator is at 14.7 volts, carefully adjust the OVV adjustor until the reading is between 5.95 and 6.00 volts.
7. Confirm Overvoltage Trigger:
8. Setting the OVV adjustor within this range ensures that the circuit will trigger overvoltage protection at 15.5 volts.